Convert Single-File Web App to SaaS
Költségvetés: -
HOURLY / AS_NEEDED
⭐ 0.00 (0)
United Kingdom
html5, javascript, php, web-design
# ACFaultPro — Full Stack SaaS Developer
### Project Overview
Fully working web app for AC/HVAC service engineers — diagnostic tool, commissioning calculators, and model-specific technical data. Built as a single HTML file (~6,000 lines), all logic and data working and tested. Needs converting to a hosted SaaS product with auth, subscription billing, and a database, then maintained and expanded ongoing.
This is not a design job. UI is built. This is a conversion, hosting, and data expansion role.
-----
### Phase 1 — Convert and Host (Fixed Scope)
- **Framework** — React or Next.js. Existing JS logic and data objects preserved exactly. No rewrites.
- **Auth** — Clerk or Auth0. Email/password login and account management.
- **Billing** — Stripe. Individual (£10/month) and Enterprise (£500/month unlimited seats). Customer Portal for self-service.
- **Database** — Supabase or PostgreSQL. User accounts, subscription status, usage logging.
- **Hosting** — Vercel or equivalent. Custom domain, SSL, production-ready.
- **Admin view** — Active subscribers, revenue, basic usage stats.
- **Data integrity** — Diagnostic data must pass an automated verification test confirming it matches the source file exactly. Required before final payment.
**Budget: £3,000–5,000. Timeline: 4–6 weeks.**
-----
### Phase 2 — Ongoing Data Expansion (Long-Term)
The app has verified diagnostic data for several Daikin platforms. The UK AC market covers 15+ years of installed equipment across 10+ manufacturers. Goal is full coverage of all major platforms.
**Each model series requires data from all manual types — not just one document:**
- **Service manual** — fault codes with causes and steps, thermistor resistance tables (A and B curves), compressor winding resistances, pressure sensor lookup tables, valve coil resistances, fan motor windings, megger specs
- **Installation manual** — pipe sizes, flare torques, factory charge per model, additional charge rate, max pipe lengths, electrical specs, MCB ratings, vacuum/pressure test procedures, field settings, PCB jumper map
- **Technical data sheet** — cooling/heating capacities, sound power levels Lw dB(A), operating temperature ranges, SEER/SCOP ratings, dimensions and weights
- **Wiring diagrams** — PCB terminal IDs, sensor locations, refrigerant circuit (where available)
Each series has 2–4 documents. All must be processed and cross-referenced. Partial entries are flagged in a dataGaps field until remaining manuals are done.
**Manufacturers (priority order):**
1. Daikin — VRV III, FTXS/RXS, FTXP/RXP, MXS multi-split, FBQ/FCQ indoor units
1. Mitsubishi Electric — PUZ-ZM, PUHZ-ZRP, PUHZ-P, PURY VRF
1. Toshiba — RAV series
1. Fujitsu — AOYG/AOTG
1. Mitsubishi Heavy Industries — FDC/FDE/FDCW
1. Panasonic, LG, Samsung, Hitachi, Midea/MDV
80–120 documents estimated for full UK coverage. PDFs provided. Each takes 2–5 hours depending on complexity. Paid hourly or per document. Regular weekly commitment required.
-----
### Technical Requirements
React/Next.js · Stripe subscriptions · Supabase/PostgreSQL · Vercel deployment · JavaScript/TypeScript · Large structured data files · SaaS subscription products
-----
### About the Data
Built over several months from manufacturer service manuals. Not AI-generated. Every value sourced and cited. Must never be modified outside the agreed process. Automated verification runs after every data addition.
-----
### What I’m Looking For
Long-term partner for both the SaaS build and ongoing data work. Clear commercial roadmap with a pilot FM company client already confirmed.
**Please include:** examples of SaaS products with Stripe billing, your approach to preserving existing JS data during conversion, Phase 1 estimate, and Phase 2 availability.
**NDA required before the source file is shared.**
Megnyitás Upworkön